

This split phase solar inverter PV3300 TLV series, capacity range from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which has AC output of single phase 110VAC/120V, split phase 220V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, it has built-in MPPT solar charge controller 80A, you can take use of sunshine freely and save electricity bills.

-
Pure sine wave output
-
Friendly user interface; MFD (multi-function display)
-
3 Steps charging
-
Overload and short-circuit protection
-
Set charging voltage/charging current
-
Battery low voltage shutdown point can be set to 10/10.5/11V
-
Set utility priority/ Battery priority
-
Set utility input wide/narrow range
-
Inverter voltage can be set to 100/110/120;frequency can be set to 50/60Hz
-
Set utility charging on/off switch
-
Built-in 80A MPPT charger

MODEL |
33- 1012 |
33- 1512 |
33- 1524 |
33- 2012 |
33- 2024 |
33- 3024 |
33- 3048 |
33- 4024 |
33- 4048 |
PV33- 5048 TLV |
PV33- 6048 TLV |
Inverter Output |
Rated power |
1KW |
1.5KW |
2KW |
3KW |
4KW |
5KW |
6KW |
Power factor |
1 |
Wave form |
Pure sine wave |
Output voltage RMS |
100V / 110V / 120VAC (200V / 220V / 240VAC, L+L) ±10% |
Output frequency |
50Hz or 60Hz (±0.3Hz) |
Inverter efficiency (peak) |
>85% |
Line mode efficiency |
>95% |
Overload |
100%<Load<110% (alarm 5min then stop output ) / 110%<Load<125% (alarm 60s then stop output) / Load > 125% (alarm 10s then stop output ) |
Surge rating |
3000VA |
4500VA |
6000VA |
9000VA |
12000VA |
15000VA |
18000VA |
Capable of starting electric motor |
1HP |
1HP |
1.5HP |
1.5HP |
2HP |
3HP |
Battery |
Battery voltage |
12VDC/24VDC |
24VDC/48VDC |
48VDC |
Minimum start voltage |
(10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Low battery voltage cut off |
10V / 10.5V / 11V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Low battery voltage alarm |
(10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
High battery voltage alarm |
(13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
High Battery Voltage Recover |
(13.8-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Save mode |
Load ≤50±20W(120V)/100±20W(220V) |
AC Input Mode |
Input waveform |
Pure sine wave |
Nominal input voltage |
200Vac / 220Vac / 240Vac |
Max input voltage |
270Vac MAX |
Input frequency |
50Hz / 60Hz (auto sensing) |
Efficiency (AC mode) |
>95% (load, full battery) |
Transfer time AC to DC |
15ms(typical) |
Solar Charger |
Maximum PV Array Power |
1250W |
1250W |
2500W |
1250W |
2500W |
2500W |
5000W |
2500W |
5000W |
5000W |
5000W |
Maximum PV Charge Current |
80A |
DC Voltage |
12V / 24V |
24V / 48V |
24V / 48V |
MPPT Range @ Operating Voltage |
16~95VDC @ 12V / 30~130VDC @ 24V |
30~130VDC @ 24V / 60~130VDC @48V |
60~130VDC @48V |
Maximum PV Array Open Circuit Voltage |
100±2Vdc / 145±2Vdc |
145±2Vdc |
145±2Vdc |
Maximum Efficiency |
>98% |
Standby Power Consumption |
<2W |
Charge Mode |
12V |
30A |
45A |
60A |
/ |
/ |
/ |
/ |
24V |
20A |
25A |
30A |
40A |
60A |
/ |
/ |
48V |
/ |
/ |
/ |
20A |
30A |
35A |
40A |
Min charge current 10A. Change by every 5A |
Dimensions |
Dimensions (W*H*D) |
277*196*466mm |
277*186*621mm |
Ship Dimensions (W*H*D) |
376*306*592mm |
376*296*747mm |
Net Weight (Solar CHG)(kg) |
17.2 |
17.7 |
21.8 |
20.7 |
25.2 |
25.5 |
38.9 |
36.5 |
38 |
39 |
Shipping Weight (Solar CHG)(kg) |
20 |
20.7 |
24.8 |
23.5 |
28.2 |
28.2 |
43 |
40.7 |
39.2 |
40.2 |
Warranty |
1year |
